Mouse anti-Mullerian hormone (AMH) ELISA kit
Referencia CSB-E13156m-96T
embalaje : 96T
Marca : Cusabio
| Size | 96T,5×96T,10×96T |
Product Details
Intra-assay Precision (Precision within an assay): CV%<15% | |||||
Three samples of known concentration were tested twenty times on one plate to assess. | |||||
Inter-assay Precision (Precision between assays): CV%<15% | |||||
Three samples of known concentration were tested in twenty assays to assess. | |||||
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | ||||||
| ||||||
ng/ml | OD1 | OD2 | Average | Corrected | ||
0 | 1.954 | 1.884 | 1.919 | 1.919 | ||
0.4 | 1.353 | 1.377 | 1.365 | 1.365 | ||
1.2 | 1.053 | 1.028 | 1.041 | 1.041 | ||
3.5 | 0.700 | 0.689 | 0.695 | 0.695 | ||
7 | 0.479 | 0.461 | 0.470 | 0.470 | ||
14 | 0.252 | 0.258 | 0.255 | 0.255 | ||
and FAQs
This Mouse AMH ELISA Kit was designed for the quantitative measurement of Mouse AMH protein in serum, plasma. It is a Competitive ELISA kit, its detection range is 0.4 ng/mL-14 ng/mL and the sensitivity is 0.25 ng/mL.
Citations
- D Dilimulati, M Cai, Y Gao, Y Zhang, X Jia,npj Biofilms and Microbiomes,2026
- Y Rao, T Xu, Y Ding, J Li, L Gao, Y Wang, W Wang,Aging Cell,2026
- M Wu, Q Zhu, J Xiong, W Tang, D Chen, L Xue, Y Feng,Nature Aging,2026
- W Xie, Y Zhang, L Fu, Y Chen, X Sun, Y Lou, Y Zhang,Journal of Nanobiotechnology,2026
- T Lu, Y Li, F Guo, C Tang, S Zhu, J Dong,Communications Biology,2026
- J Zhu, P Wu, Y Ma, Z Peng, H Fa, L Qin, M Geng,Nature Communications,2026
- S Wei, D Chen, J Wang, C Wu, W Tang, L Xue,Journal of Advanced Research,2026
- Y Zhou, Y Lu, Y Luo, J Li, W Chen, Y Zheng,Journal of Hazardous Materials,2025
- Y Wu, Y Chen, S Wang, T Wu, J Zhang,Reproductive Toxicology,2026
- J Tang, Y Chen, M Zhou, L Zhao, Y Li, M Li,International Journal of Molecular Sciences,2025
Customer Reviews and Q&A
Sample type: Serum
Sample species: Mouse
Sample dilution: No dilution
Review: The serum samples I tested were mice, and the basic curves were normal with a good fit
By Anonymous
Sample type: Serum
Sample species: Mouse
Sample dilution: No dilution
Review: I used CSB-E13156m to detect the normal serum level of sex hormone AMH. The OD value of the standard curve was 1.505-0.161, the OD value of the sample was 0.659-1.122, and the R value of the standard curve was 0.99984.
By Anonymous
Sample type: Serum
Sample species: Mouse
Sample dilution: 1:2/1:5/1:10
Review: I used CSB-E13156m to measure the standard OD values of 2.03, 1.81, 1.27, 0.81, 0.56, 0.29. The product is very convenient and easy to use.
By Anonymous
Target Background
(From Uniprot)
STRING:
UniGene:


