Human IL-6/Interleukin-6 ELISA Kit PicoKine®

Referencia EK0410

embalaje : 96wells/kit

Marca : Boster Bio

Contact local distributor :


Teléfono : +1 850 650 7790

Human IL-6/Interleukin-6 ELISA Kit PicoKine®

IL6 ELISA kit for Human

Human IL-6/Interleukin-6 ELISA Kit PicoKine® (96 Tests). Quantitate Human IL6 in cell culture supernatants, serum and plasma ( heparin, EDTA, citrate). Sensitivity: 0.3pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 535 publication(s).

Product Info Summary

SKU: EK0410
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma ( heparin, EDTA, citrate).

Product Name

Human IL-6/Interleukin-6 ELISA Kit PicoKine®

SKU/Catalog Number

EK0410

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human IL-6/Interleukin-6 ELISA Kit PicoKine® (96 Tests). Quantitate Human IL6 in cell culture supernatants, serum and plasma ( heparin, EDTA, citrate). Sensitivity: 0.3pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human IL-6/Interleukin-6 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0410)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: E.coli; Immunogen sequence: P29-M212

Sensitivity

<0.3 pg/ml

Assay Range

4.69 pg/ml - 300 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK0410 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0410 is reactive to IL6 in Human samples

Validated Sample Types

cell culture supernatants, serum and plasma ( heparin, EDTA, citrate).

Application Guarantee

EK0410 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of IL6

The human interferon-beta 2 gene (IFNB2) product is identical to that for the B-cell stimulation factor-2 (BSF-2), the hybridoma growth factor (HGF) ("interleukin-6"), and the hepatocyte stimulating factor (HSF). Proteins derived from this gene mediate the plasma protein response to tissue injury (acute-phase response) and regulate the growth and differentiation of both B and T cells. Interleukin-6 (IL6) has come to be regarded as a potential osteoporotic factor because it has stimulatory effects on cells of the osteoclast lineage, and, thus, may play a role in the pathogenesis of bone loss associated with estrogen deficiency. IL-6 has many roles essential to the regulation of the immune response, hematopoiesis, and bone resorption. It is involved not only in the hepatic acute phase response but also in adipose tissue metabolism, lipoprotein lipase activity, and hepatic triglyceride secretion. Overproduction of IL-6, a proinflammatory cytokine, is associated with a spectrum of age-related conditions including cardiovascular disease, osteoporosis, arthritis, type 2 diabetes, certain cancers, periodontal disease, frailty, and functional decline. BSF-2 is a novel interleukin consisting of 184 amino acids. The standard product used in this kit is recombinant human IL-6, consisting of 184 amino acids with the molecular mass of 20.3kDa.

Kit Components

Catalog Number Description Quantity
EK0410-CAP Anti-Human IL6 Pre-coated 96-well strip microplate 1
EK0410-ST Human IL6 Standard 2 vials, 10 ng/tube
EK0410-DA Human IL6 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Question

Hello Support: I purchased Human IL-6 ELISA Kit but I have some questions, could you please give advice on staining technique? Is it possible to use only few wells for analysis of several samples and save other plates for further studies? Lastly, do I need to buy any software for data analysis, or Excel will be enough?

Verified Customer

Verified customer

Asked: 2020-04-30

Answer

The Human IL-6 ELISA Kit comes with 96 well with removable strips, so you can remove as many strips as you need before using it, then store the remaining strips in the pouch with desiccant, sealed it tightly and put in storage at 4C. For your data analysis excel will do. All you need to do is to calculate the average absorbance values and create a standard curve, then interpolate the sample concentrations from the standard curve.

Boster Scientific Support

Answered: 2020-04-30

Question

Q: can I use heparin plasma as samples in Human IL-6 Picokine® ELISA Kit (Catalog # EK0410)?

Verified Customer

Verified customer

Asked: 2020-03-20

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can irreversibly bind metal ions from the functional domain of IL-6 causing disruption of its protein structure. IL-6 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes needed for detection and block the antigen antibody reaction. We have tested the IL-6 ELISA, treating samples with a number of anticoagulants and decided that heparin, EDTA or citrate can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2020-03-20

Question

What is the expiration date of EK0525 and EK0410 from the time of manufacturing, 6 months or 1 year?

Verified customer

Asked: 2019-12-17

Answer

Expiration is based on storage temperature. Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles.

Boster Scientific Support

Answered: 2019-12-17

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2019-11-22

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/elisa-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/elisa-data-analysis-instructions

Boster Scientific Support

Answered: 2019-11-22

Question

I purchased Human IL-6 ELISA Kit and I reconstitute with acetic acid and the coating buffer is alkaline solution of pH 9.6. I am concern with the pH change and possibly affects my results? Please let me know

Verified Customer

Verified customer

Asked: 2019-08-30

Answer

We recommend to use for coating buffers, the standard PBS rather than alkaline carbonate buffers for this antibody Human IL-6 ELISA Kit

Boster Scientific Support

Answered: 2019-08-30

Question

Is the Human IL-6 ELISA Kit have been tested with saliva samples? Do you have any suggestions?

Verified Customer

Verified customer

Asked: 2019-08-15

Answer

The Human IL-6 ELISA Kit is suitable to use in saliva samples and the usual protocol would apply. No need for pre-treatment of sample before assay.

Boster Scientific Support

Answered: 2019-08-15

Question

Q: how are cell lysates prepared for use in Picokine® ELISA kits?

Verifie

Usted podría estar interesado también en los siguientes productos:



Referencia
Descripción
Cond.
Precio Sin IVA
EK0376-SC
 96Tests