Human AMY1A (Alpha-amylase 1A) CLIA Kit for Quantitative Detection

Referencia NB-22-40401-96

embalaje : 96T

Marca : Neo Biotech

Contact local distributor :


Teléfono : +1 850 650 7790

✓ 1-Year Performance Guarantee | SDS & Datasheet Included | Expert Tech Support | Covered by

General Information

Short DescriptionThis human AMY1A kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes in serum, plasma and other biological fluids.
ApplicationsCLIA
ReactivityHuman
Sensitivity0.19ng/mL
Detection Limit0.31~20ng/mL
NoteFOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.

Product Properties

Storage InstructionIf unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time3.5h
DetectionChemiluminescence

Target Information

Gene Symbol
Gene ID
Uniprot ID
SpecificityThis kit recognizes Human AMY1 in samples. No significant cross-reactivity or interference between Human AMY1 and analogues was observed.
Sample TypeSerum, plasma and other biological fluids

Additional Info

Function Calcium-binding enzyme that initiates starch digestion in the oral cavity. Catalyzes the hydrolysis of internal (1->4)-alpha-D-glucosidic bonds, yielding a mixture of maltose, isomaltose, small amounts of glucose as well as small linear and branched oligosaccharides called dextrins.
Protein Name Alpha-Amylase 1a
1 -4-Alpha-D-Glucan Glucanohydrolase 1
Salivary Alpha-Amylase
Database Links
Cellular Localisation Secreted
Alternative CLIA Names Alpha-Amylase 1a CLIA kit
1 -4-Alpha-D-Glucan Glucanohydrolase 1 CLIA kit
Salivary Alpha-Amylase CLIA kit
AMY1A CLIA kit
AMY1 CLIA kit
Specificity This kit recognizes Human AMY1 in samples. No significant cross-reactivity or interference between Human AMY1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 85-98 92
EDTA plasma(n=8) 95-111 103
Cell culture media(n=8) 87-98 93

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 0.92 1.76 8.22 0.97 1.83 8.71
Standard deviation 0.10 0.13 0.55 0.08 0.14 0.54
CV (%) 10.87 7.39 6.69 8.25 7.65 6.20

Citations

Product Review

Well-cited Academic Publications
KO-Validated 700+ Lines
Technical Support Expert Scientific Team
1-Year Guarantee Antibodies & Proteins