This kit is based on Double antibody-Sandwich ELISA detection method and takes 4h assay time. The microplate provided in this kit has been precoated with anti IL-8 antibody. Add standard and properly diluted sample into relevant well respectively. After incubation, wash unbound components. Add biotinylated detection antibody. Then, it binds with IL-8 bound to precoated antibody. Wash unbound components and add HRP-Streptavidin Conjugate (SABC). Wash unbound components again and add TMB substrate solution. Then, TMB was catalyzed by HRP to produce a blue color product that turned yellow after adding a stop solution. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of IL-8 in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
- Catalogue No.:
- EHS0003
- Alias:
- Interleukin-8 ELISA Kit, IL-8 ELISA Kit, C-X-C motif chemokine 8 ELISA Kit, Chemokine ELISA Kit, C-X-C motif) ligand 8 ELISA Kit, Emoctakin ELISA Kit, Granulocyte chemotactic protein 1 ELISA Kit, GCP-1 ELISA Kit, Monocyte-derived neutrophil chemotactic factor ELISA Kit, MDNCF ELISA Kit, Monocyte-derived neutrophil-activating peptide ELISA Kit, MONAP ELISA Kit, Neutrophil-activating protein 1 ELISA Kit, NAP-1 ELISA Kit, Protein 3-10C ELISA Kit, T-cell chemotactic factor ELISA Kit, CXCL8 ELISA Kit, IL8 ELISA Kit
- Species:
- Horse
- Range:
- 15.625-1000pg/ml
- Sensitivity:
- 9.375pg/ml
| Size | |
|---|---|
| 96T | Inquiry |
- Product Name
- Horse IL-8(Interleukin 8) ELISA Kit
- Alias
- Interleukin-8 ELISA Kit, IL-8 ELISA Kit, C-X-C motif chemokine 8 ELISA Kit, Chemokine ELISA Kit, C-X-C motif) ligand 8 ELISA Kit, Emoctakin ELISA Kit, Granulocyte chemotactic protein 1 ELISA Kit, GCP-1 ELISA Kit, Monocyte-derived neutrophil chemotactic factor ELISA Kit, MDNCF ELISA Kit, Monocyte-derived neutrophil-activating peptide ELISA Kit, MONAP ELISA Kit, Neutrophil-activating protein 1 ELISA Kit, NAP-1 ELISA Kit, Protein 3-10C ELISA Kit, T-cell chemotactic factor ELISA Kit, CXCL8 ELISA Kit, IL8 ELISA Kit
- Catalogue No.
- EHS0003
- Size
- 48T/96T
- Species
- Horse
- UniProt ID
- O62812
- Sample Type
- Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
- Detection Method
- Sandwich ELISA, Double Antibody
- Detection Wavelength
- OD450
- Reaction Duration
- 4 hours
- Range
- 15.625-1000pg/ml
- Sensitivity
- 9.375pg/ml
- Storage
- 2-8°C(Sealed), Don't cryopreserve.
- Specificity
- Specifically binds with IL-8 , no obvious cross reaction with other analogues.
- ELISA Kit Components
Kit Components Item Size(48T) Size(96T) Storage Condition for Opened Kit E001 ELISA Microplate(Dismountable) 8×6 8×12 Put the rest strips into a sealed foil bag with the desiccant. Stored for 1 month at 2-8°C; Stored for 12 month at -20°C E002 Lyophilized Standard 1vial 2vial Put the rest standards into a desiccant bag. Stored for 1 month at 2-8°C; Stored for 12 month at -20°C E003 Biotin-labeled Antibody(Concentrated, 100X) 60ul 120ul 2-8°C (Avoid Direct Light) E034 HRP-Streptavidin Conjugate(SABC, 100X) 60ul 120ul E024 TMB Substrate 5ml 10ml E039 Sample Dilution Buffer 10ml 20ml 2-8°C E040 Antibody Dilution Buffer 5ml 10ml E049 SABC Dilution Buffer 5ml 10ml E026 Stop Solution 5ml 10ml E038 Wash Buffer(Concentrated, 25X) 15ml 30ml E006 Plate Sealer 3 pieces 5 pieces E007 Product Description 1 copy 1 copy - Required Instruments and Reagents
-
- Microplate reader (wavelength: 450nm)
- 37°C incubator (CO2 incubator for cell culture is not recommenced.)
- Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
- Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
- Sterile tubes and Eppendorf tubes with disposable tips
- Absorbent paper and loading slot
- Deionized or distilled water
- Assay Procedure Summary
-
- Step 1: Add 100ul standard or sample into each well, seal the plate and statically incubate for 90 minutes at 37°C.
- Washing: Wash the plate twice without immersing.
- Step 2: Add 100ul biotin-antibody working solution, seal the plate and statically incubate for 60 minutes at 37°C.
- Washing: Wash the plate three times and immerse for 1min each time.
- Step 3: Add 100ul HRP-Streptavidin Conjugate (SABC) working solution, seal the plate and statically incubate for 30 minutes at 37°C.
- Washing: Wash the plate five times and immerse for 1min each time.
- Step 4: Add 90ul TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37°C. (Accurate TMB visualization control is required.)
- Step 5: Add 50ul stop solution. Read at 450nm immediately and calculate.
- Standard Curve
-
This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.)
Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.
- Recovery
-
Add a certain amount of IL-8 into the sample. Calculate the recovery by comparing the measured value with the expected amount of IL-8 in the sample.
Sample Type Recovery Range(%) Average(%) serum(n=10) 89-102 94 EDTA plasma(n=10) 86-103 95 Heparin plasma(n=10) 87-99 95 - Linearity
-
Dilute the sample with a certain amount of IL-8 at 1:2, 1:4 and 1:8 to get the recovery range.
Sample Type 1:2 1:4 1:8 serum(n=10) 87-103% 90-105% 85-98% EDTA plasma(n=10) 82-101% 85-99% 82-93% Heparin plasma(n=10) 82-98% 83-94% 88-100% - Precision(%)
-
Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.
Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.
Item Intra-assay Precision Inter-assay Precision Sample 1 2 3 1 2 3 n 20 20 20 20 20 20 Mean (pg/ml) 31.93 120.6 511 32.16 123.6 523 Standard deviation 1.48 7.1 28.21 1.63 6.44 25.94 CV(%) 4.62 5.89 5.52 5.07 5.21 4.96 - Stability
-
Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.
ELISA kit(n=5) 37°C for 1 month 2-8°C for 6 months 2-8°C for 12 months Average(%) 80 95-100 85-98
- Journal:
- International Journal of Molecular Sciences
- Author:
- Department of Biochemistry, Faculty of Veterinary Medicine, University of Life Sciences in Lublin, 20-033 Lublin, Poland
- Cited Date:
- 2025-11-07
- Product: