Rat GL Beta (Galactosidase, Beta) CLIA Kit for Quantitative Detection

Cat# NB-22-41880-96

Size : 96T

Brand : Neo Biotech

Contact local distributor :


Phone : +1 850 650 7790

Short Description :This rat GL Beta kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes in serum, plasma and other biological fluids.
Applications:CLIA
Reactivity:Rat
Sensitivity:18.75pg/mL
Detection Limit:31.25~2000pg/mL
Note:FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Storage Instruction:If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time:3.5h
Detection:Chemiluminescence
Specificity:This kit recognizes Rat GL Beta in samples. No significant cross-reactivity or interference between Rat GL Beta and analogues was observed.
Sample Type:Serum, plasma and other biological fluids
Specificity This kit recognizes Rat GLβ in samples. No significant cross-reactivity or interference between Rat GLβ and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 92-109 99
EDTA plasma(n=8) 88-99 93
Cell culture media(n=8) 92-108 100

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 93.84 254.47 811.24 89.37 256.68 789.77
Standard deviation 10.05 29.93 70.90 11.15 27.23 89.17
CV (%) 10.71 11.76 8.74 12.48 10.61 11.29