Human IL-17/IL-17A ELISA Kit PicoKine®
Cat# EK0430
Size : 96wells/kit,withremovablestrips.
Brand : Boster Bio
Product Info Summary
| SKU: | EK0430 |
|---|---|
| Size: | 96 wells/kit, with removable strips. |
| Reactive Species: | Human |
| Application: | ELISA |
| Sample Types: | cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). |
Product Name
Human IL-17/IL-17A ELISA Kit PicoKine®
SKU/Catalog Number
EK0430
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human IL-17/IL-17A ELISA Kit PicoKine® (96 Tests). Quantitate Human IL17A in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 1pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human IL-17/IL-17A ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0430)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: E.coli; Immunogen sequence: I20-A155
Sensitivity
<1 pg/ml
Assay Range
31.2 pg/ml - 2,000 pg/ml
Standard Dilution Instructions

See datasheet of EK0430 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0430 is reactive to IL17A in Human samples
Validated Sample Types
cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Application Guarantee
EK0430 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of IL17A
IL-17 is an inflammatory cytokine produced primarily by a unique lineage of CD4 T cells that plays critical roles in the pathogenesis of multiple autoimmune diseases. Interleukin-17 is expressed by activated T cells and is 57% identical to the 17- to 26-kD secretory glycoprotein encoded by gene 13 of the herpesvirus saimiri (HVS-13). IL17 induces nuclear factor kappa-B and the expression of IL6, intercellular adhesion molecule-1, granulocyte macrophage colony-stimulating factor,and prostaglandin E2, as well as the maturation of CD34 positive hematopoietic precursors into neutrophils. Anti-IL17 antibodies significantly inhibited osteoclast formation induced by culture media of RA synovial tissues. The standard product used in this kit is recombinant human IL-17, consisting of 136 amino acids with the molecular mass of 16KDa.
Kit Components
| Catalog Number | Description | Quantity |
|---|---|---|
| EK0430-CAP | Anti-Human IL17A Pre-coated 96-well strip microplate | 1 |
| EK0430-ST | Human IL17A Standard | 2 vials, 10 ng/tube |
| EK0430-DA | Human IL17A Biotinylated antibody (100x) | 100ul |
| AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
| AR1106-1 | Sample Diluent | 30ml |
| AR1106-2 | Antibody Diluent | 12ml |
| AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
| AR1104 | Color Developing Reagent (TMB) | 10ml |
| AR1105 | Stop Solution | 10ml |
| AR1106-5 | Wash Buffer (25x) | 20ml |
| PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Validation Standard Curve O.D. At 450nm
| Concentration (pg/ml) | 0 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 | 2000 |
| O.D. | 0.056 | 0.11 | 0.156 | 0.244 | 0.457 | 0.868 | 1.677 | 2.955 |
Data Example Images
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect IL17A,
| Application | Dilution | Species |
|---|---|---|
| Dilution ratio of 1:1 | concentration in serum and plasma is less than the lowest standard | 31.2 pg/ml. |
Some articles we found to cite concentrations of IL17A in samples: 24076595 (Pubmed IDs).
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human IL-17/IL-17A ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
| Intra-Assay Precision | Inter-Assay Precision | |||||
|---|---|---|---|---|---|---|
| Sample | 1 | 2 | 3 | 1 | 2 | 3 |
| n | 16 | 16 | 16 | 24 | 24 | 24 |
| Mean (pg/ml) | 54 | 276 | 763 | 52 | 257 | 703 |
| Standard deviation | 3.88 | 19.59 | 34.33 | 4.52 | 18.5 | 37.96 |
| CV (%) | 7.2% | 7.1% | 4.5% | 8.7% | 7.2% | 5.4% |