| Size | |
|---|---|
| 96T | Inquiry |
- Product Name
- Human Anti-SARS-CoV2(S)IgM ELISA Kit
- Alias
- SARS-CoV-2(S) IgM ELISA Kit
- Catalogue No.
- EH4951
- Size
- 48T/96T
- Species
- Human
- Sample Type
- Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
- Detection Method
- indirect elisa
- Detection Wavelength
- OD450
- Reaction Duration
- 1.5 hours
- Range
- 0.781-50ng/ml
- Sensitivity
- 0.469ng/ml
- Storage
- 2-8°C(Sealed), Don't cryopreserve.
- Specificity
- Specifically binds with anti-2019 nCoV (S) IgM , no obvious cross reaction with other analogues.
- Required Instruments and Reagents
-
- Microplate reader (wavelength: 450nm)
- 37°C incubator (CO2 incubator for cell culture is not recommenced.)
- Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
- Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
- Sterile tubes and Eppendorf tubes with disposable tips
- Absorbent paper and loading slot
- Deionized or distilled water
- Assay Procedure Summary
-
- Standard Curve
-
This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.)
Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.
- Recovery
-
Add a certain amount of anti-2019 nCoV (S) IgM into the sample. Calculate the recovery by comparing the measured value with the expected amount of anti-2019 nCoV (S) IgM in the sample.
Sample Type Recovery Range(%) Average(%) serum(n=10) 89-99 93 EDTA plasma(n=10) 89-105 95 Heparin plasma(n=10) 87-104 96 - Linearity
-
Dilute the sample with a certain amount of anti-2019 nCoV (S) IgM at 1:2, 1:4 and 1:8 to get the recovery range.
Sample Type 1:2 1:4 1:8 serum(n=10) 86-105% 86-97% 85-101% EDTA plasma(n=10) 86-97% 85-101% 83-99% Heparin plasma(n=10) 80-99% 81-100% 85-97% - Precision(%)
-
Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.
Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.
Item Intra-assay Precision Inter-assay Precision Sample 1 2 3 1 2 3 n 20 20 20 20 20 20 Mean (ng/ml) 1.54 6.3 24.12 1.59 5.91 23.77 Standard deviation 0.08 0.35 1.26 0.09 0.24 0.81 CV(%) 5.3 5.54 5.21 5.49 4.02 3.42 - Stability
-
Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.
ELISA kit(n=5) 37°C for 1 month 2-8°C for 6 months 2-8°C for 12 months Average(%) 80 95-100 85-98
- Journal:
- International Journal of Biological Macromolecules
- Author:
- Laboratory of Infection and Immunology, School of Medical Technology, Xinxiang Medical University, Xinxiang 453003, PR China.
- Cited Date:
- 2024-03-22
- Product:


