Rat COL1 (Collagen Type Ⅰ) ELISA Kit

Referência E-EL-R3008-96T

Tamanho : 96T

Marca : Elabscience

Contactar o distribuidor local :


Telefone : +1 850 650 7790

Rat COL1(Collagen Type Ⅰ) ELISA Kit (E-EL-R3008)

loading Resources
Rat COL1(Collagen Type Ⅰ) ELISA Kit - 1
  • Rat COL1(Collagen Type Ⅰ) ELISA Kit - 1
  • Rat COL1(Collagen Type Ⅰ) ELISA Kit - 2
  • Rat COL1(Collagen Type Ⅰ) ELISA Kit - 3
All Size Price Qty
96T $ 609.00
- +
48T $ 487.00
- +
24T $ 150.00
- +
96T*5 Inquire /
96T*10 Inquire /

For research use only.

Product Summary
Sensitivity 4.69 ng/mL
Detection Range 7.81-500 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Rat
Specificity This kit recognizes Rat COL1 in samples.No significant cross-reactivity or interference between Rat COL1 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Colorimetric method, ELISA, Sandwich
Assay Type Sandwich-ELISA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃
Expiration Date 12 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
500 2.335 2.393 2.364 2.292
250 1.767 1.729 1.748 1.676
125 1.048 1.054 1.051 0.979
62.5 0.556 0.534 0.545 0.473
31.25 0.301 0.295 0.298 0.226
15.63 0.176 0.176 0.176 0.104
7.81 0.127 0.127 0.127 0.055
0 0.068 0.076 0.072 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 23.570 48.620 209.590 22.840 53.340 193.760
Standard deviation 1.020 2.260 13.140 1.480 4.110 13.620
CV(%) 4.320 4.640 6.270 6.460 7.710 7.030
Recovery
The recovery of Rat COL1 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 89-100 97
EDTA plasma (n=8) 95-103 99
Cell culture media (n=8) 88-94 91
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Rat COL1 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 98-107 93-105 98-109
Average 102 99 105
1:4 Range 97-110 92-103 88-98
Average 102 99 93
1:8 Range 88-102 97-111 94-103
Average 95 103 99
Stability
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
/ Variation range of 37°C mean
concentration / 2-8°C mean
Sample 1(n=16) 85.23-93.86
Sample 2(n=16) 95.93-112.54
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Rat COL1. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat COL1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat COL1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Rat COL1. You can calculate the concentration of Rat COL1 in the samples by comparing the OD of the samples to the standard curve.
Gene ID 29393
Uniport ID P02454
Research Area Signal Transduction
Rat COL1(Collagen Type Ⅰ) ELISA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

Species

{{relatedElisaPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

Videos

Competitive ELISA Operation Guide Video Sandwich ELISA Operation Guide Video
确定

Você também pode estar interessado nos seguintes produtos:



Referência
Descrição
Cond.
Price Bef. VAT
AAH-INF-1-8
 8SampleKit 
AAH-ANG-1000-8
 8SampleKit 
AAH-CYT-1-8
 8SampleKit