RayBio® Mouse Custom Adiponectin SpeedELISA is a sandwich-based immunoassay with a simplified work flow for the rapid, quantitative measurement of mouse Adiponectin in only 3 hours. Suitable for serum, plasma, cell culture supernatants, or lysate samples.

Contact Us for Bulk Request

Product Description

Specifications

Size1 Plate Kit, 2 Plate Kit, 5 Plate Kit
SpeciesMouse
Accession Number
Q60994
Gene Id
11450
Gene Symbols
ADIPOQ, ACRP30, ACDC, APM1
Protein Name / Synonyms
Adiponectin (30 kDa adipocyte complement-related protein) (Adipocyte complement-related 30 kDa protein) (ACRP30) (Adipocyte, C1q and collagen domain-containing protein) (Adipose most abundant gene transcript 1 protein) (apM-1) (Gelatin-binding protein)
Quantitative/Semi-QuantitativeQuantitative
Solid Support
96-well Microplate
Design PrincipleSandwich-based
Method Of DetectionColorimetric
Research AreaCancer, Inflammation, Energy Metabolism, Obesity & Metabolic Disease
Shipping TypeBlue ice
Storage-20°C

Product Features

  • Compressed workflow with only one wash step and three incubation steps
  • 3 hours total processing time
  • Strip plates and additional reagents allow for use in multiple experiments
  • Quantitative protein detection
  • Establishes normal range
  • The best products for confirmation of antibody array data

Application Notes

Kit Components
  • Streptavidin-Coated 96-well Strip Microplate
  • Wash Buffer
  • Stop Solution
  • Assay Diluent(s)
  • Lyophilized Standard
  • Biotinylated Capture Antibody
  • HRP Conjugated Detection Antibody
  • TMB One-Step Substrate
Other Materials Required
  • Distilled or deionized water
  • Precision pipettes to deliver 2 µl to 1 µl volumes
  • Adjustable 1-25 µl pipettes for reagent preparation
  • 100 µl and 1 liter graduated cylinders
  • Tubes to prepare standard and sample dilutions
  • Absorbent paper
  • Microplate reader capable of measuring absorbance at 450nm
  • Log-log graph paper or computer and software for ELISA data analysis
Protocol Outline
  1. Prepare all reagents, samples and standards as instructed in the manual.
  2. Add 70 µl of the Antibody Cocktail to each well.
  3. Incubate 10 minutes at RT.
  4. Add 50 µl of sample or standard to each well.
  5. Incubate 2 h at RT.
  6. Wash Wells
  7. Add 100 µl of TMB One-Step Substrate Reagent to each well.
  8. Incubate 30 min at RT.
  9. Add 50 µl of Stop Solution to each well.
  10. Read at 450 nm immediately.

Storage/Stability

May be stored for up to 6 months at 2° to 8°C from the date of shipment. Opened Microplate Wells or reagents may be store for up to 1 month at 2° to 8°C. Return unused wells to the pouch containing desiccant pack, reseal along entire edge. Reconstituted standard can be stored at -80°C for up to 1 week.
Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.